PERFORMANCE ANALYSIS OF NATURAL AND INDUCED DRAFT COOLING TOWER IN SUMMER AND MONSOON SEASONS

Authors

  • Gaurav Kumar Dwivedi

Keywords:

Thermal power, Cooling tower, Natural Draft

Abstract

In India 68% of total electricity generate by coal based thermal power plant. Now a day’s thermal power plant is
very efficient and gradually increasing the generation of electricity. Where water is the most usable part in the thermal power plant, it is used for the generation of the steam. Water resources are easily available in plenty amount, but usage of water has to be done very carefully to from the environment point of view. In the thermal power plant large amount of water is used for the steam generation and it also recirculated. For the continuous recirculation of water, it is necessary to cool it. For this purpose, cooling tower is used in the thermal power plant. Cooling tower is an essential part of the thermal power plant. It cools the hot water and releases heat in the environment. A cooling tower cools water by a combination of heat and mass transfer. Water to be cooled is distributed in the tower by spray nozzles, splash bars, or film-type fill, which exposes a very large water surface area to atmospheric air. So here i’m analyzing the performance of natural and Induced draft cooling tower in different seasons. And here we have used the analytical method for the analysis of cooling tower. This method of analysis is quite popular and have been referred by most of the researchers working in this field. The result coming through this method is quite comparable with practical scenarios. 

References

A. Kumar, H. Banothu, M. Dilawar, and M. Kumar, “Analysis of performance of natural draft cooling tower at optimized injection height,”

Int. J. Mech. Eng. Technol., vol. 9, no. 7, pp. 687–694, 2018.

P. R. Chitale, R. K. Gamare, S. K. Chavan, R. Suresh, and A. S. Yekane, “Design and Analysis of Cooling Tower,” J. Eng. Res. Appl., vol.

, no. 4, pp. 79–84, 2018.

V. S. Kumar and R. Mathews, “Performance Analysis and Optimization of Cooling Tower,” Int. J. Sci. Res. Publ., vol. 8, no. 4, pp. 225–

C. N. Nataraj, “Study on Induced Draft Cooling Tower Performance Analysis in Captive Power Plant,” Int. Res. J. Eng. Technol., vol. 4, no.

, pp. 414–421, 2017.

K. S. Vishwakarma et al., “Study the factors on which efficiency of cooling tower can be critically acclaimed (A case Study),” J. Eng. Res.

Appl. www.ijera.com ISSN, vol. 5, no. 43, pp. 2248–962273, 2015.

J. M. Variava, “PERFORMANCE ANALYSIS OF COOLING TOWER IN PROCESS INDUSTRY,” no. 6, pp. 1722–1730, 2017.

M. V. . Satish Kumar, “Performance Analysis of Cooling Tower,” Int. J. Eng. Trends Technol., vol. 38, no. 8, pp. 442–448, 2016.

P. Ajit, P. Dash, K. K. Panda, A. K. Yadav, and V. Sharma, “Design of mechanical draftcooling tower and determination of thermal efficiency,” vol. 1, no. 4, pp. 191–197, 2016.

S. Kulkarni and A. Goswami, “Studies and Experimentation on Cooling Towers: A Review,” Int. Res. J. Eng., pp. 279–282, 2015.

J. H. Alsuwaidi, O. R. Al Hamdan, and M. M. I. Hammad, “Natural Draft Cooling Tower Performance Evaluation,” vol. 6, no. 4, pp. 1499–

, 2015.

P. V Dave, “Thermal Performance Analysis of Natural Draft Cooling Tower Simulation using CFX,” vol. 3, no. 1, pp. 1–4, 2015.

Shashank Tiwari and Prof. Mahendra Agrawal, “Analysis of Counter Flow Induced Draft Cooling Tower using Taguchi Method,” Int. J.

Eng. Res., vol. V4, no. 06, pp. 292–297, 2015.

E. Journal, S. A. Ahmad, A. Ahmad, A. Butt, and T. Waqas, “Performance Improvement of Mechanical Induced Draft Cooling Tower by

Using Aluminum as Fill Medium,” vol. 3, no. 11, pp. 10–14, 2016.

B. S. Pushpa, V. Vaze, and P. T. Nimbalkar, “Performance Evaluation of Cooling Tower in Thermal Power Plant - A Case Study of RTPS ,

Karnataka Different Radius Vs Loss of Temperature,” no. 2, pp. 110–114, 2014.

R. M. A, “Performance Improvement of Natural Draft Cooling Tower,” Int. J. Eng. Res. Rev., vol. 2, no. 1, pp. 7–15, 2014.

T. Jagadeesh, “Performance Analysis of the Natural Draft Cooling Tower in Different Seasons,” IOSR J. Mech. Civ. ng., vol. 7, no. 5, pp.

Downloads

Published

31-03-2021

How to Cite

Kumar Dwivedi, G. (2021). PERFORMANCE ANALYSIS OF NATURAL AND INDUCED DRAFT COOLING TOWER IN SUMMER AND MONSOON SEASONS. International Journal for Research Publication and Seminar, 12(1), 1–8. Retrieved from https://jrps.shodhsagar.com/index.php/j/article/view/84

Issue

Section

Original Research Article